• Ultra rapid warming - up
• Low phase noise
• Wide working temperature range
• Low power consumption
• Small dimensions
• Frequency range: 8-13 MHz
SPECIFICATIONS
Parameter
Symbol
Conditions
Value
Unit
Remark
Min
Norm
Max
Frequency range
fo
8
10
13
MHz
Aging
Per day
Af/fo
After 30 days of
0.5
ppb
Per month
continuous
30
Per year
work
100
Phase noise
L(f)
10 Hz
-118
dBc/Hz
for
100 Hz
-145
f0=10 MHz
1 kHz
-155
10 kHz
-160
Allan deviation
11
3
E-11
Frequency deviation in operating temperature range
-50°Ñ ÷ +70°Ñ
±0.1
ppm
Frequency deviation from supply voltage change
12 V ±10%
1.0
RF output
Uo
Rh = 50 Ohm
450
500
550
ìÂ
Tuning range
Uynp = 0 ÷ 8V
±0.5
Positive tilt
Supply voltage
Vcc
10.8
12.0
13.2
Â
Warm-up time to 1Å-7
t = 25°Ñ
15
ñ
Power
warm-up
P
1.5
Âò
consumption
0.3
Environment temperature
Storage
-60°Ñ ÷ +70°Ñ
Operating
Vibrations
1 - 500 Hz, 5g
Mechanical shock
75 g, 1 - 5 ms
humidity
98% by 35°Ñ