• Low phase noise
• Wide working temperature range
• Low power consumption
• Low sensitivity to mechanical vibration
• Frequency range: 8-13 MHz
SPECIFICATIONS
Parameter
Symbol
Conditions
Value
Unit
Remark
Min
Norm.
Max
Frequency range
fo
8
10
13
MHz
Aging
Per day
Af/fo
After 30 days of
0.1
ppb
Per month
continuous
Per year
work
30
50
Phase noise
L(f)
10 Hz
-140
-130
dBc/Hz
for
100 Hz
-155
-150
f0=10 MHz
1kHz
-160
10 kHz
-165
-158
Allan deviation
12
5
E-12
Frequency deviation in operating temperature range
-60°Ñ ÷ +70°Ñ
±50
Frequency deviation from supply voltage change
12 V ±10%
±0.5
RF output
Uo
Rh = 50 Ohm
450
500
550
mV
Tuning range
Uynp = 0 ÷ 8V
ppm
Positive tilt
Supply voltage
Vcc
10.8
12.0
13.2
V
Warm-up time to 1Å-7
t= 25°Ñ
3
min
Power
warm-up
P
1.5
W
Consumption
Steady state
t = 25°Ñ
0.25
Environment temperature
Storage
-60°Ñ ÷ +85°Ñ
Operating
Vibrations
10-2000 Hz, 5g
Mechanical shock
150 g, 0,3 - 1 ms
Humidity
98% by 40°Ñ